Wesbild Centre - Vernon multi-use facilityWesbild Centre - Vernon multi-use facility
Where the
Excitement Begins!
Greater Vernon Arenas

The Venue > Technical Information: Page 2

Technical Information - continued...

Architect's Rendering of Front EntryPRODUCTION OFFICE
A Production Office (dimensions 22' x 42') is available on the lower floor of the facility. The production office is equipped with three permanent telephone lines. The upstairs press area measures 48' x 16 ' and can also be used as a Production Office.

LOCKS & KEYS
Locker/dressing rooms may be secured with locks and keys. Keys for each room may be checked out through the Operation's Office. All persons who sign out keys will be responsible for return of the keys at the conclusion of the event.

PYROTECHNICS
A permit is required for any pyrotechnics used in the building or anywhere on the premises. There will be a designated lockable room used for storing pyro. Building will supply fire extinguishers at the show's expense.

LOAD-IN
Show load-in is located at the North End of the arena, approximately 50' from the arena floor. There are two 14' x 16' roll-up doors. There is adequate parking for 5 buses or trucks outside the load-in area. (Arrangements may be made to park additional vehicles & Show Power).

FORKLIFT
The arena owns one 6,000 lb. forklift that is available for rent. Powered by propane, it has a lift height of 15' and is equipped with side shift. Fork length is 4' (6' with extensions).

EMERGENCY SYSTEMS
Fire sprinklers, smoke sensors and fire extinguishers are located throughout the arena and office areas. An emergency generator will provide backup sound and light power in case of a power failure.

ELECTRICAL POWER

Events Power
There is a Total Capacity of 300KVA (833) at 120/208V for the Event Power, they are distributed through three 400A, 120/208V, 3 phase, 4 wire events power distribution centers, located at the north end of the arena. Each distribution center consist of a disconnect switch and a splitter box as well as five point 400A camlok connector system (3 hots, 1 neutral, 1 ground).

Catwalks
On each Catwalk there are 5 120V, 20A receptacles (each on its own circuit) spaced out evenly, and there is a 4-pin 5-wire 60A unfused pin and sleeve receptacle located near the centerline.

Lighting
There is a low voltage lighting system, which controls the lighting through the facility. There are three L.V. Master Stations controlling all luminaries and they are located in the operation office (138), Administration office (206) and the media box (302) Only the upper concourse lights are dimmer operated. The dimmer system can be set in the operation office and there are 2 - 4 button scene selectors located in the administration office and the media box.

A TV Satellite truck connection (4P-5W-60A unfused weather proof pin and sleeve receptacle) located at the southeast exterior wall of the facility.